[{"@context":"http:\/\/schema.org\/","@type":"BlogPosting","@id":"https:\/\/wiki.edu.vn\/en2fr\/wiki28\/decharge-partielle-wikipedia\/#BlogPosting","mainEntityOfPage":"https:\/\/wiki.edu.vn\/en2fr\/wiki28\/decharge-partielle-wikipedia\/","headline":"D\u00e9charge partielle – Wikipedia wiki","name":"D\u00e9charge partielle – Wikipedia wiki","description":"before-content-x4 D\u00e9change di\u00e9lectrique localis\u00e9e sous contrainte haute tension after-content-x4 En g\u00e9nie \u00e9lectrique, d\u00e9charge partielle ( PD ) est une d\u00e9gradation","datePublished":"2017-09-28","dateModified":"2017-09-28","author":{"@type":"Person","@id":"https:\/\/wiki.edu.vn\/en2fr\/wiki28\/author\/lordneo\/#Person","name":"lordneo","url":"https:\/\/wiki.edu.vn\/en2fr\/wiki28\/author\/lordneo\/","image":{"@type":"ImageObject","@id":"https:\/\/secure.gravatar.com\/avatar\/c9645c498c9701c88b89b8537773dd7c?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/c9645c498c9701c88b89b8537773dd7c?s=96&d=mm&r=g","height":96,"width":96}},"publisher":{"@type":"Organization","name":"Enzyklop\u00e4die","logo":{"@type":"ImageObject","@id":"https:\/\/wiki.edu.vn\/wiki4\/wp-content\/uploads\/2023\/08\/download.jpg","url":"https:\/\/wiki.edu.vn\/wiki4\/wp-content\/uploads\/2023\/08\/download.jpg","width":600,"height":60}},"image":{"@type":"ImageObject","@id":"https:\/\/upload.wikimedia.org\/wikipedia\/commons\/thumb\/e\/e5\/Partial_discharge.svg\/220px-Partial_discharge.svg.png","url":"https:\/\/upload.wikimedia.org\/wikipedia\/commons\/thumb\/e\/e5\/Partial_discharge.svg\/220px-Partial_discharge.svg.png","height":"141","width":"220"},"url":"https:\/\/wiki.edu.vn\/en2fr\/wiki28\/decharge-partielle-wikipedia\/","wordCount":4951,"articleBody":" (adsbygoogle = window.adsbygoogle || []).push({});before-content-x4D\u00e9change di\u00e9lectrique localis\u00e9e sous contrainte haute tension (adsbygoogle = window.adsbygoogle || []).push({});after-content-x4En g\u00e9nie \u00e9lectrique, d\u00e9charge partielle ( PD ) est une d\u00e9gradation di\u00e9lectrique localis\u00e9e (DB) (qui ne fait pas compl\u00e8tement combler l’espace entre les deux conducteurs) d’une petite partie d’un syst\u00e8me d’isolation \u00e9lectrique solide ou fluide (EI) sous contrainte haute tension (HV).Bien qu’une d\u00e9charge de corona (CD) soit g\u00e9n\u00e9ralement r\u00e9v\u00e9l\u00e9e par une lueur ou une d\u00e9charge de brosse relativement stable (BD) dans l’air, les d\u00e9charges partielles dans le syst\u00e8me d’isolation solide ne sont pas visibles. La MP peut se produire dans un milieu isolant gazeux, liquide ou solide. Il commence souvent dans les vides de gaz, tels que les vides dans l’isolation \u00e9poxy solide ou les bulles dans l’huile de transformateur. La d\u00e9charge partielle prolong\u00e9e peut \u00e9roder l’isolation solide et finalement entra\u00eener une rupture de l’isolation. (adsbygoogle = window.adsbygoogle || []).push({});after-content-x4Table of ContentsM\u00e9canisme de d\u00e9charge [ modifier ]] Circuit \u00e9quivalent PD [ modifier ]] Courants de d\u00e9charge partielle [ modifier ]] Syst\u00e8mes de d\u00e9tection et de mesure des d\u00e9charges [ modifier ]] Syst\u00e8me de mesure partiel de la d\u00e9charge [ modifier ]] Le principe de la mesure partielle des d\u00e9bits [ modifier ]] Configuration d’\u00e9talonnage [ modifier ]] M\u00e9thodes de laboratoire [ modifier ]] M\u00e9thodes de test sur le terrain [ modifier ]] Effets de la d\u00e9charge partielle dans les syst\u00e8mes d’isolation [ modifier ]] Surveillance des \u00e9v\u00e9nements de sortie partiels dans les transformateurs et les r\u00e9acteurs [ modifier ]] Normes internationales et guides informatifs [ modifier ]] Voir \u00e9galement [ modifier ]] Les r\u00e9f\u00e9rences [ modifier ]] Bibliographie [ modifier ]] Liens externes [ modifier ]] M\u00e9canisme de d\u00e9charge [ modifier ]] Une d\u00e9charge partielle dans l’isolation solide. Lorsqu’une \u00e9tincelle saute l’\u00e9cart dans le vide rempli de gaz, un petit courant circule dans les conducteurs, att\u00e9nu\u00e9 par le r\u00e9seau de diviseur de tension CX, CY, CZ en parall\u00e8le avec la capacit\u00e9 en vrac CB La MP commence g\u00e9n\u00e9ralement dans des vides, des fissures ou des inclusions dans un di\u00e9lectrique solide, \u00e0 des interfaces conductrices di\u00e9lectriques dans les di\u00e9lectriques solides ou liquides, ou dans des bulles dans les di\u00e9lectriques liquides. \u00c9tant donn\u00e9 que les PD sont limit\u00e9s \u00e0 seulement une partie de l’isolation, les d\u00e9charges ne font que partiellement combler la distance entre les \u00e9lectrodes. La MP peut \u00e9galement se produire le long de la fronti\u00e8re entre diff\u00e9rents mat\u00e9riaux isolants. Les d\u00e9charges partielles dans un mat\u00e9riau isolant sont g\u00e9n\u00e9ralement initi\u00e9es dans des vides remplis de gaz dans le di\u00e9lectrique. Parce que la constante di\u00e9lectrique du vide est consid\u00e9rablement inf\u00e9rieure \u00e0 celle du di\u00e9lectrique environnant, le champ \u00e9lectrique \u00e0 travers le vide est significativement plus \u00e9lev\u00e9 que celui sur une distance \u00e9quivalente de di\u00e9lectrique. Si la contrainte de tension \u00e0 travers le vide est augment\u00e9e au-dessus de la tension de cr\u00e9ation de la couronne (CIV) pour le gaz dans le vide, l’activit\u00e9 PD commencera dans le vide. (adsbygoogle = window.adsbygoogle || []).push({});after-content-x4La MP peut \u00e9galement se produire le long de la surface des mat\u00e9riaux isolants solides si le champ \u00e9lectrique tangentiel de surface est suffisamment \u00e9lev\u00e9 pour provoquer une d\u00e9gradation le long de la surface de l’isolateur. Ce ph\u00e9nom\u00e8ne se manifeste g\u00e9n\u00e9ralement sur les isolateurs de la ligne a\u00e9rienne, en particulier sur les isolateurs contamin\u00e9s pendant les jours d’humidit\u00e9 \u00e9lev\u00e9e. Les lignes a\u00e9riennes utilisent l’air comme milieu d’isolation. Circuit \u00e9quivalent PD [ modifier ]] Le circuit \u00e9quivalent d’un di\u00e9lectrique incorporant une cavit\u00e9 peut \u00eatre mod\u00e9lis\u00e9 comme un diviseur de tension capacitif parall\u00e8le avec un autre condensateur. Le condensateur sup\u00e9rieur du diviseur repr\u00e9sente la combinaison parall\u00e8le des capacit\u00e9s en s\u00e9rie avec le vide et le condensateur inf\u00e9rieur repr\u00e9sente la capacit\u00e9 du vide. Le condensateur parall\u00e8le repr\u00e9sente la capacit\u00e9 non ind\u00e9pendante restante de l’\u00e9chantillon. Courants de d\u00e9charge partielle [ modifier ]] Chaque fois que la d\u00e9charge partielle est initi\u00e9e, des impulsions de courant transitoire \u00e0 haute fr\u00e9quence appara\u00eetront et persisteront pour les nanosecondes \u00e0 une microseconde, puis dispara\u00eetront et r\u00e9apparaissent \u00e0 plusieurs reprises lorsque l’onde de tension passe par la travers\u00e9e z\u00e9ro. Le PD se produit pr\u00e8s de la tension de cr\u00eate \u00e0 la fois positive et n\u00e9gative. Les impulsions PD sont faciles \u00e0 mesurer en utilisant la m\u00e9thode du transducteur de courant \u00e0 haute fr\u00e9quence (HFCT). Le transducteur actuel est serr\u00e9 autour du cas du bo\u00eetier du composant test\u00e9. La gravit\u00e9 de la MP est mesur\u00e9e en mesurant l’intervalle de rafale entre la fin d’une rafale et le d\u00e9but de la prochaine rafale. \u00c0 mesure que la panne d’isolation s’aggrave, l’intervalle de rafale raccourcira en raison de la rupture qui se produit \u00e0 des tensions inf\u00e9rieures. Cet intervalle d’\u00e9clatement continuera de raccourcir jusqu’\u00e0 ce qu’un point critique de 2 millisecondes soit atteint. \u00c0 ce point de 2 ms, la d\u00e9charge est tr\u00e8s proche de la travers\u00e9e z\u00e9ro et \u00e9chouera avec une d\u00e9charge compl\u00e8te et une d\u00e9faillance majeure. La m\u00e9thode HFCT doit \u00eatre utilis\u00e9e en raison de la petite ampleur et de la courte dur\u00e9e de ces \u00e9v\u00e9nements PD. La m\u00e9thode HFCT est effectu\u00e9e pendant que le composant test\u00e9 reste sous tension et charg\u00e9e. C’est compl\u00e8tement non intrusif. Une autre m\u00e9thode de mesure de ces courants consiste \u00e0 mettre une petite r\u00e9sistance de mesure de courant en s\u00e9rie avec l’\u00e9chantillon, puis \u00e0 afficher la tension g\u00e9n\u00e9r\u00e9e sur un oscilloscope via un c\u00e2ble coaxial appari\u00e9. Lorsque la PD, l’arc ou l’\u00e9tincelle se produit, les ondes \u00e9lectromagn\u00e9tiques se propagent du site de d\u00e9faut dans toutes les directions qui contactent le r\u00e9servoir de transformateur et se d\u00e9placent vers la terre (c\u00e2ble de sol) o\u00f9 le HFCT est situ\u00e9 pour capturer n’importe quel EMI ou EMP dans le transformateur, le disjoncteur, PT , CT, c\u00e2ble HV, MCSG, LTC, LA, g\u00e9n\u00e9rateur, grands moteurs HV, etc. La d\u00e9tection des impulsions \u00e0 haute fr\u00e9quence identifiera l’existence de d\u00e9charges partielles, d’arc ou d’\u00e9tincelles. Une fois la PD ou l’arc d\u00e9tect\u00e9, l’\u00e9tape suivante consiste \u00e0 localiser la zone de d\u00e9faut. En utilisant la m\u00e9thode d’\u00e9mission acoustique (AE), 4 capteurs AE ou plus sont plac\u00e9s sur la coquille du transformateur o\u00f9 les wavedata AE et HFCT sont collect\u00e9s en m\u00eame temps. Le filtrage de passe-bande est utilis\u00e9 pour \u00e9liminer les interf\u00e9rences des bruits du syst\u00e8me. Syst\u00e8mes de d\u00e9tection et de mesure des d\u00e9charges [ modifier ]] Avec la mesure de d\u00e9charge partielle, l’\u00e9tat di\u00e9lectrique de l’\u00e9quipement haute tension peut \u00eatre \u00e9valu\u00e9 et l’arborescence \u00e9lectrique dans l’isolation peut \u00eatre d\u00e9tect\u00e9e et localis\u00e9e. La mesure partielle de la d\u00e9charge peut localiser la partie endommag\u00e9e d’un syst\u00e8me isol\u00e9. Les donn\u00e9es recueillies lors des tests de d\u00e9charge partielle sont compar\u00e9es aux valeurs de mesure du m\u00eame c\u00e2ble recueillies lors du test d’acceptation ou aux normes de contr\u00f4le de la qualit\u00e9 d’usine. Cela permet une classification simple et rapide de l’\u00e9tat di\u00e9lectrique (nouveau, fortement \u00e2g\u00e9, d\u00e9fectueux) de l’appareil test\u00e9 et des mesures de maintenance et de r\u00e9paration appropri\u00e9es peuvent \u00eatre planifi\u00e9es et organis\u00e9es \u00e0 l’avance. La mesure partielle de la d\u00e9charge est applicable aux c\u00e2bles et accessoires avec divers mat\u00e9riaux d’isolation, tels que le c\u00e2ble en poly\u00e9thyl\u00e8ne ou en papier couvert de plomb (PILC). La mesure partielle des d\u00e9bits est r\u00e9guli\u00e8rement effectu\u00e9e pour \u00e9valuer l’\u00e9tat du syst\u00e8me d’isolation des machines rotatives (moteurs et g\u00e9n\u00e9rateurs), transformateurs et appareils de commutation isol\u00e9s en gaz. Syst\u00e8me de mesure partiel de la d\u00e9charge [ modifier ]] Un syst\u00e8me de mesure de d\u00e9charge partiel se compose essentiellement de: un c\u00e2ble ou un autre objet test\u00e9 un condensateur de couplage de la conception d’inductance faible une alimentation haute tension avec un faible bruit de fond Connexions \u00e0 haute tension un filtre \u00e0 haute tension pour r\u00e9duire le bruit de fond de l’alimentation un d\u00e9tecteur de d\u00e9charge partielle Logiciel PC pour analyse Un syst\u00e8me de d\u00e9tection de d\u00e9charge partielle pour l’\u00e9quipement \u00e9lectrique \u00e9lectrique sous service et sous tension: un c\u00e2ble, un transformateur ou tout \u00e9quipement d’alimentation MV \/ HV Bande passante de d\u00e9tection \u00e0 haute fr\u00e9quence (UHF) 300 MHz-1,5 GHz Bande passante de courant de courant \u00e0 haute fr\u00e9quence (HFCT) 500 kHz-50 MHz Microphone \u00e0 ultrasons avec fr\u00e9quence centrale 40 kHz Capteur de contact acoustique avec bande passante de d\u00e9tection 20 kHz – 300 kHz Capteur TEV ou condensateur de couplage 3 MHz-100 MHz Syst\u00e8me d’analyse \u00e0 r\u00e9solution de phase pour comparer le calage des impulsions \u00e0 la fr\u00e9quence AC Le principe de la mesure partielle des d\u00e9bits [ modifier ]] Un certain nombre de sch\u00e9mas de d\u00e9tection de d\u00e9charge et de m\u00e9thodes de mesure partiel des d\u00e9bits ont \u00e9t\u00e9 invent\u00e9s car l’importance de la MP a \u00e9t\u00e9 r\u00e9alis\u00e9e au d\u00e9but du si\u00e8cle dernier. Les courants de d\u00e9charge partiels ont tendance \u00e0 \u00eatre de courte dur\u00e9e et ont des temps de hausse dans le royaume nanoseconde. Sur un oscilloscope, les d\u00e9charges apparaissent comme des \u00e9v\u00e9nements rafra\u00eechissants espac\u00e9s qui se produisent au sommet de l’ewave sinueux. Les \u00e9v\u00e9nements al\u00e9atoires sont des arcs ou des \u00e9tincelles.La fa\u00e7on habituelle de quantifier l’amplitude des d\u00e9charges partielle est dans les picocoulombs. L’intensit\u00e9 de la d\u00e9charge partielle est affich\u00e9e en fonction du temps. Une analyse automatique des r\u00e9flectogrammes collect\u00e9s lors de la mesure partielle de la d\u00e9charge – en utilisant une m\u00e9thode appel\u00e9e r\u00e9flectom\u00e9trie du domaine temporel (TDR) – permet l’emplacement des irr\u00e9gularit\u00e9s d’isolation. Ils sont affich\u00e9s dans un format de cartographie de d\u00e9charge partielle. Une repr\u00e9sentation li\u00e9e \u00e0 la phase des d\u00e9charges partielles fournit des informations suppl\u00e9mentaires, utiles pour l’\u00e9valuation de l’appareil test\u00e9. Configuration d’\u00e9talonnage [ modifier ]] Le changement de charge r\u00e9el qui se produit en raison d’un \u00e9v\u00e9nement PD n’est pas directement mesurable, par cons\u00e9quent, charge apparente est utilis\u00e9 \u00e0 la place. La charge apparente (q) d’un \u00e9v\u00e9nement PD est la charge qui, si elle est inject\u00e9e entre les terminaux de l’appareil test\u00e9, modifierait la tension \u00e0 travers les bornes par un montant \u00e9quivalent \u00e0 l’\u00e9v\u00e9nement PD. Cela peut \u00eatre mod\u00e9lis\u00e9 par l’\u00e9quation: q = C bD ( DANS c) {displayStyle q = c_ {b} delta (v_ {c})} La charge apparente n’est pas \u00e9gale \u00e0 la quantit\u00e9 r\u00e9elle de charge changeante sur le site PD, mais peut \u00eatre directement mesur\u00e9e et calibr\u00e9e. \u00abCharge apparente\u00bb est g\u00e9n\u00e9ralement exprim\u00e9e en picocoulombs. Ceci est mesur\u00e9 en calibrant la tension des pointes par rapport aux tensions obtenues \u00e0 partir d’une unit\u00e9 d’\u00e9talonnage d\u00e9charg\u00e9e dans l’instrument de mesure. L’unit\u00e9 d’\u00e9talonnage est assez simple en fonctionnement et comprend simplement un g\u00e9n\u00e9rateur d’ondes carr\u00e9 en s\u00e9rie avec un condensateur connect\u00e9 \u00e0 travers l’\u00e9chantillon. Habituellement, ceux-ci sont d\u00e9clench\u00e9s optiquement pour permettre l’\u00e9talonnage sans entrer dans une zone de haute tension dangereuse. Les calibrateurs sont g\u00e9n\u00e9ralement d\u00e9connect\u00e9s lors des tests de d\u00e9charge. M\u00e9thodes de laboratoire [ modifier ]] Circuits de d\u00e9tection de PD \u00e0 large bandeDans la d\u00e9tection de la bande large, l’imp\u00e9dance comprend g\u00e9n\u00e9ralement un circuit RLC \u00e0 r\u00e9sonance parall\u00e8le \u00e0 faible Q. Ce circuit a tendance \u00e0 att\u00e9nuer la tension excitante (g\u00e9n\u00e9ralement entre 50 et 60 Hz) et \u00e0 amplifier la tension g\u00e9n\u00e9r\u00e9e en raison des d\u00e9charges. Circuits de d\u00e9tection \u00e0 r\u00e9glage (bande \u00e9troite) M\u00e9thodes de pont de d\u00e9charge diff\u00e9rentielle M\u00e9thodes acoustiques et ultrasoniques M\u00e9thodes de test sur le terrain [ modifier ]] Les mesures sur le terrain emp\u00eachent l’utilisation d’une cage Faraday et l’alimentation \u00e9nergisante peut \u00e9galement \u00eatre un compromis de l’id\u00e9al. Les mesures sur le terrain sont donc sujettes au bruit et peuvent par cons\u00e9quent \u00eatre moins sensibles. [d’abord] [2] Les tests de PD de qualit\u00e9 d’usine sur le terrain n\u00e9cessitent un \u00e9quipement qui ne peut pas \u00eatre facilement disponible, par cons\u00e9quent, d’autres m\u00e9thodes ont \u00e9t\u00e9 d\u00e9velopp\u00e9es pour une mesure sur le terrain qui, bien que non aussi sensibles ou pr\u00e9cises que les mesures standardis\u00e9es, sont beaucoup plus pratiques. Par n\u00e9cessit\u00e9, les mesures du champ doivent \u00eatre rapides, s\u00fbres et simples si elles doivent \u00eatre largement appliqu\u00e9es par les propri\u00e9taires et les op\u00e9rateurs des actifs MV et HV. Tensions de terre transitoires (TEV) sont des pics de tension induits \u00e0 la surface de la travail m\u00e9tallique environnante. Les TEV ont \u00e9t\u00e9 d\u00e9couverts pour la premi\u00e8re fois en 1974 par le Dr John Reeves [3] de Technologie EA . Les TEV se produisent parce que la d\u00e9charge partielle cr\u00e9e des pointes actuelles dans le conducteur et donc \u00e9galement dans le m\u00e9tal terrestre entourant le conducteur. Le Dr John Reeves a \u00e9tabli que les signaux TEV sont directement proportionnels \u00e0 l’\u00e9tat de l’isolation pour tous les appareils de commutation du m\u00eame type mesur\u00e9s au m\u00eame point. Les lectures TEV sont mesur\u00e9es en DBMV. Les impulsions de TEV sont pleines de composants \u00e0 haute fr\u00e9quence et donc la ferronnerie terrestre pr\u00e9sente une imp\u00e9dance consid\u00e9rable au sol. Par cons\u00e9quent, des pointes de tension sont g\u00e9n\u00e9r\u00e9es. Ceux-ci resteront sur la surface int\u00e9rieure de la ferronnerie environnante (\u00e0 une profondeur d’environ 0,5 \u00b5m en acier doux \u00e0 100 MHz) et se d\u00e9roulent vers la surface ext\u00e9rieure partout o\u00f9 il y a une discontinuit\u00e9 \u00e9lectrique dans le m\u00e9tal. Il y a un effet secondaire par lequel les ondes \u00e9lectromagn\u00e9tiques g\u00e9n\u00e9r\u00e9es par la d\u00e9charge partielle g\u00e9n\u00e8rent \u00e9galement des TEV sur la ferronnerie environnante – la ferronnerie environnante agissant comme une antenne. Les TEV sont un ph\u00e9nom\u00e8ne tr\u00e8s pratique pour mesurer et d\u00e9tecter des d\u00e9charges partielles car elles peuvent \u00eatre d\u00e9tect\u00e9es sans \u00e9tablir de connexion \u00e9lectrique ou enlever les panneaux. Bien que cette m\u00e9thode puisse \u00eatre utile pour d\u00e9tecter certains probl\u00e8mes d’appareillage de commutation et de suivi de surface sur les composants internes, la sensibilit\u00e9 n’est pas susceptible d’\u00eatre suffisante pour d\u00e9tecter les probl\u00e8mes dans les syst\u00e8mes de c\u00e2bles di\u00e9lectriques solides. Ultrasonique La mesure repose sur le fait que la d\u00e9charge partielle \u00e9mettra des ondes sonores. La fr\u00e9quence des \u00e9missions est le bruit “blanc” dans la nature et produit donc des ondes de structure \u00e0 ultrasons \u00e0 travers le composant \u00e9lectrique solide ou liquide rempli de liquide. En utilisant un capteur ultrasonique n\u00e9 \u00e0 l’ext\u00e9rieur de l’\u00e9l\u00e9ment \u00e0 l’examen, une d\u00e9charge partielle interne peut \u00eatre d\u00e9tect\u00e9e et situ\u00e9e lorsque le capteur est plac\u00e9 le plus proche de la source. M\u00e9thode HFCT Cette m\u00e9thode est id\u00e9ale pour d\u00e9tecter et d\u00e9terminer la gravit\u00e9 de la MP par mesure d’intervalle d’\u00e9clatement. Plus les rafales se rapprochent de la \u00abtravers\u00e9e de tension z\u00e9ro\u00bb, plus le d\u00e9faut PD est grave et critique. L’emplacement de la zone de faille est accompli en utilisant AE d\u00e9crit ci-dessus. Champ \u00e9lectromagn\u00e9tique La d\u00e9tection ramasse les ondes radio g\u00e9n\u00e9r\u00e9es par la d\u00e9charge partielle. Comme indiqu\u00e9 pr\u00e9c\u00e9demment, les ondes radio peuvent g\u00e9n\u00e9rer des TEV sur la ferronnerie environnante. Des mesures plus sensibles, en particulier \u00e0 des tensions plus \u00e9lev\u00e9es, peuvent \u00eatre obtenues en utilisant des antennes UHF construites ou une antenne externe mont\u00e9e sur des entretoises isolantes dans le m\u00e9tal environnant. Un coupleur directionnel La d\u00e9tection ramasse les signaux \u00e9manant d’une d\u00e9charge partielle. Cette m\u00e9thode est id\u00e9ale pour les articulations et les accessoires, les capteurs \u00e9tant situ\u00e9s sur les couches seminiques de l’articulation ou des accessoires. [4] Effets de la d\u00e9charge partielle dans les syst\u00e8mes d’isolation [ modifier ]] Une fois commenc\u00e9, la MP provoque une d\u00e9t\u00e9rioration progressive des mat\u00e9riaux isolants, entra\u00eenant finalement une d\u00e9gradation \u00e9lectrique. Les effets de la MP dans les c\u00e2bles et l’\u00e9quipement haute tension peuvent \u00eatre tr\u00e8s graves, ce qui entra\u00eene finalement une d\u00e9faillance compl\u00e8te. L’effet cumulatif des d\u00e9charges partiels dans les di\u00e9lectriques solides est la formation de nombreux canaux de d\u00e9charge en ramification partiellement, un processus appel\u00e9 arborescence. Les \u00e9v\u00e9nements de d\u00e9charge r\u00e9p\u00e9titive provoquent une d\u00e9t\u00e9rioration irr\u00e9versible m\u00e9canique et chimique du mat\u00e9riau isolant. Les dommages sont caus\u00e9s par l’\u00e9nergie dissip\u00e9e par des \u00e9lectrons ou des ions \u00e0 haute \u00e9nergie, la lumi\u00e8re ultraviolette des d\u00e9charges, l’ozone attaquant les parois vides et se fissurant lorsque les processus de d\u00e9gradation chimique lib\u00e8rent les gaz \u00e0 haute pression. La transformation chimique du di\u00e9lectrique a \u00e9galement tendance \u00e0 augmenter la conductivit\u00e9 \u00e9lectrique du mat\u00e9riau di\u00e9lectrique entourant les vides. Cela augmente la contrainte \u00e9lectrique dans la r\u00e9gion de l’espace (jusqu’\u00e0 pr\u00e9sent) non affect\u00e9e, acc\u00e9l\u00e9rant le processus de panne. Un certain nombre de di\u00e9lectriques inorganiques, y compris le verre, la porcelaine et le mica, sont nettement plus r\u00e9sistants aux dommages \u00e0 la MP que les di\u00e9lectriques organiques et polym\u00e8res. Dans les c\u00e2bles \u00e0 haute tension isol\u00e9s en papier, les d\u00e9charges partielles commencent comme de petits trous d’\u00e9pingle p\u00e9n\u00e9trant les enroulements en papier qui sont adjacents au conducteur \u00e9lectrique ou \u00e0 la gaine externe. Au fur et \u00e0 mesure que l’activit\u00e9 PD progresse, les d\u00e9charges r\u00e9p\u00e9titives provoquent finalement des changements chimiques permanents au sein des couches papier affect\u00e9es et impr\u00e9gnant le liquide di\u00e9lectrique. Au fil du temps, des arbres carbonis\u00e9s partiellement conduits se forment. Cela exerce une plus grande contrainte sur l’isolation restante, conduisant \u00e0 une croissance plus approfondie de la r\u00e9gion endommag\u00e9e, au chauffage r\u00e9sistif le long de l’arbre et \u00e0 la carbonisation ult\u00e9rieure (parfois appel\u00e9e suivi ). Cela finit par se terminer dans la d\u00e9faillance di\u00e9lectrique compl\u00e8te du c\u00e2ble et, g\u00e9n\u00e9ralement, une explosion \u00e9lectrique. Les d\u00e9charges partielles dissipent l’\u00e9nergie sous forme de chaleur, de son et de lumi\u00e8re. Le chauffage localis\u00e9 \u00e0 partir de PD peut provoquer une d\u00e9gradation thermique de l’isolation. Bien que le niveau de chauffage PD soit g\u00e9n\u00e9ralement faible pour les fr\u00e9quences de courant continu et de ligne \u00e9lectrique, il peut acc\u00e9l\u00e9rer les d\u00e9faillances dans des \u00e9quipements haute fr\u00e9quence haute tension. L’int\u00e9grit\u00e9 de l’isolation dans l’\u00e9quipement haute tension peut \u00eatre confirm\u00e9e en surveillant les activit\u00e9s de MP qui se produisent \u00e0 travers la dur\u00e9e de vie de l’\u00e9quipement. Pour garantir la fiabilit\u00e9 de l’approvisionnement et la durabilit\u00e9 op\u00e9rationnelle \u00e0 long terme, la MP en \u00e9quipement \u00e9lectrique \u00e0 haute tension doit \u00eatre surveill\u00e9e \u00e9troitement avec les signaux d’alerte pr\u00e9coce pour l’inspection et l’entretien. La MP peut g\u00e9n\u00e9ralement \u00eatre \u00e9vit\u00e9e gr\u00e2ce \u00e0 une conception minutieuse et \u00e0 une s\u00e9lection de mat\u00e9riaux. Dans un \u00e9quipement critique \u00e0 haute tension, l’int\u00e9grit\u00e9 de l’isolation est confirm\u00e9e \u00e0 l’aide d’un \u00e9quipement de d\u00e9tection PD pendant le stade de fabrication ainsi que p\u00e9riodiquement gr\u00e2ce \u00e0 la dur\u00e9e de vie utile de l’\u00e9quipement. La pr\u00e9vention et la d\u00e9tection des PD sont essentielles pour assurer un fonctionnement fiable et \u00e0 long terme d’\u00e9quipements \u00e0 haute tension utilis\u00e9s par les services publics d’\u00e9nergie \u00e9lectrique. Surveillance des \u00e9v\u00e9nements de sortie partiels dans les transformateurs et les r\u00e9acteurs [ modifier ]] En utilisant des coupleurs et capteurs UHF, des signaux de d\u00e9charge partiels sont d\u00e9tect\u00e9s et transport\u00e9s vers une unit\u00e9 de contr\u00f4le principale o\u00f9 un processus de filtrage est appliqu\u00e9 pour rejeter l’interf\u00e9rence. L’amplitude et la fr\u00e9quence des impulsions de d\u00e9charge partielle UHF sont num\u00e9ris\u00e9es, analys\u00e9es et trait\u00e9es afin de g\u00e9n\u00e9rer une alarme de donn\u00e9es de d\u00e9charge partielle appropri\u00e9e, un contr\u00f4le de supervision et une alarme d’acquisition de donn\u00e9es (SCADA). Selon le fournisseur du syst\u00e8me, les sorties de d\u00e9charge partielle sont accessibles via un r\u00e9seau local, via le modem ou m\u00eame une visionneuse Web via. Normes internationales et guides informatifs [ modifier ]] IEC 60060-2: 1989 Techniques de test \u00e0 haute tension – Partie 2: Syst\u00e8mes de mesure CEI 60270: 2000 \/ BS EN 60270: 2001 “Techniques de test \u00e0 haute tension – Mesures de d\u00e9charge partielle” CEI 61934: 2006 “Mat\u00e9riaux et syst\u00e8mes isolants \u00e9lectriques – Mesure \u00e9lectrique de la PD sous un temps de mont\u00e9e court et des impulsions de tension r\u00e9p\u00e9titive” CEI 60664-4: 2007 “Coordination d’isolation pour l’\u00e9quipement dans les syst\u00e8mes \u00e0 basse tension – Partie 4: Examen de la contrainte de tension \u00e0 haute fr\u00e9quence” CEI 60034-27: 2007 “Machines \u00e9lectriques rotatives – mesures de d\u00e9charge partielle hors ligne sur l’isolation de l’enroulement du stator des machines \u00e9lectriques rotatives” IEEE STD 436 \u2122 -1991 (R2007) “Guide de l’IEEE pour effectuer des mesures Corona (d\u00e9charge partielle) sur les transformateurs \u00e9lectroniques” IEEE 1434\u20132000 “Guide d’utilisation d’essai IEEE \u00e0 la mesure des d\u00e9charges partielles dans les machines rotatives” IEEE 400-2001 “Guide IEEE pour les tests sur le terrain et l’\u00e9valuation de l’isolation des syst\u00e8mes de c\u00e2bles d’alimentation blind\u00e9s” PD IEC \/ TS 62478: 2016 “Techniques de test \u00e0 haute tension – Mesure des d\u00e9charges partielles par des m\u00e9thodes \u00e9lectromagn\u00e9tiques et acoustiques” Voir \u00e9galement [ modifier ]] Les r\u00e9f\u00e9rences [ modifier ]] ^ D. F. Warne Progr\u00e8s en ing\u00e9nierie haute tension , Institution of Electrical Engineers, 2004 ISBN 0-85296-158-8, page 166 ^ Davies, N.; Jones, D. (2008-06-12). “Tester la distribution de commutation pour une sortie partielle en laboratoire et dans le domaine”. Record de la conf\u00e9rence du Symposium international de l’IEEE 2008 sur l’isolation \u00e9lectrique . IEEE. pp. 716\u2013719. est ce que je: 10.1109 \/ elinsl.2008.4570430 . ISBN 978-1-4244-2091-9 . ^ Davies, N., Tang, J.C.Y., Shiel, P., (2007), Avantages et exp\u00e9riences de mesures de d\u00e9charge partielle non intrusives sur l’appareillage de commutation MV, CIRED 2007, papier 0475. ^ Craatz P., Plath R., Heinrich R., Kalkner W.: Mesure et emplacement sensibles sur le site PD \u00e0 l’aide de capteurs de coupleur directionnels dans des articulations pr\u00e9fabriqu\u00e9es de 110 kV, 11th Ish99, Londres, papier 5.317 p5 Bibliographie [ modifier ]] Fondamentaux d’ing\u00e9nierie haute tension, E.Kuffel, W.S. Zaengl, Pub. Pergamon Press. Premi\u00e8re \u00e9dition, 1992 ISBN 0-08-024213-8 Di\u00e9lectriques d’ing\u00e9nierie, volume IIA, Propri\u00e9t\u00e9s \u00e9lectriques des mat\u00e9riaux isolants solides: structure mol\u00e9culaire et comportement \u00e9lectrique, R. Bartnikas, R. M eichhorn, ASTM Special Technical Publication 783, ASTM, 1982 Di\u00e9lectriques d’ing\u00e9nierie, Volume I, Corona Mesurement and Interpretation, R. Bartnikas, E. J. McMahon, ASTM Special Technical Publication 669, ASTM, 1979, ISBN 0-8031-0332-8 \u00c9lectricit\u00e9 aujourd’hui, mai 2009, page 28 – 29 Pommerenke D., Strehl T., Heinrich R., Kalkner W., Schmidt F., Wei\u00dfenberg W.: Discrimination entre la MP interne et d’autres impulsions utilisant des capteurs de couplage directionnels sur les syst\u00e8mes de c\u00e2bles \u00e0 haute tension, les transactions IEEE sur les di\u00e9lectriques et l’isolation \u00e9lectrique, Vol .6, n \u00b0 6, 99 d\u00e9cembre, pp. 814\u2013824 Liens externes [ modifier ]] (adsbygoogle = window.adsbygoogle || []).push({});after-content-x4"},{"@context":"http:\/\/schema.org\/","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"item":{"@id":"https:\/\/wiki.edu.vn\/en2fr\/wiki28\/#breadcrumbitem","name":"Enzyklop\u00e4die"}},{"@type":"ListItem","position":2,"item":{"@id":"https:\/\/wiki.edu.vn\/en2fr\/wiki28\/decharge-partielle-wikipedia\/#breadcrumbitem","name":"D\u00e9charge partielle – Wikipedia wiki"}}]}]